Get in Touch

Contact Form Demo

TEF Water Series Electromagnetic Flowmeter

TEF Series flowmeter is a Faraday’s law based electromagnetic flowmeter, which measures the volumetric flowrate of conductive fluids. TEF has compact and remote (field) version and customers could choose each of them according to their applications. With the FLASH integrated, 32-bit ultra-low power MCU, the product shows a perfect performance of integration, operation and calculation, thus make the measurement stable, reliable and unaffected by flow patterns. TEF is widely used for flow measurement of conductive liquid in Chemical, Oil & Gas, Water & Waste Water, Metal, Textile, Paper & Pulp, Life Sciences, Food & Beverage, Environmental Protection, Power & Energy, and other process industries.

Features

  • No Moving Parts Long-Term Stability
  • No Pressure Loss
  • Self-Adjustable Exciting Frequency High Stability, Low Power Consumption
  • Full Digital Processing Perfect EMC Compatibility
  • Ultra-Low EMI Power Supply Compatibility for Wide Range Voltage
  • Intelligent Diagnositic Functions Empty Pipe / Excitor Failure / Limit Alarm, etc

Applications

  • Water & Waste Water: Waste Water / Water / Surface Water, etc.
  • Metal, Minerals & Mining: Cooling Water / Slurry / Waste Water, etc.
  • Paper&Pulp: Pulp / Additives / White Water / Waste Water, etc.
  • Chemical: Chemical Fluids and Products
  • Food & Beverage: Liquor / Beverage / Dairy, etc.
  •  New Industries & Applications: Chip / Semiconductor Industry, IDC, etc.

Specifications

Item Performance
Nominal Diameter DN (mm) 03 ~ 2600
Conductivity ≥ 5 μS/cm, Water ≥ 20 μS/cm
Maximum Pressure 4.0 MPa
Process Temperature Neoprene Liner: -20°C ~ +60°C
PTFE Liner: -40°C ~ +130°C
PFA Liner: -20°C ~ +150°C
High Temperature PFA Liner: -20°C ~ +180°C
PU Liner: -10°C ~ +65°C
Ceramic Liner: -10°C ~ +180°C
F46 Liner: -40°C ~ +80°C
Flow Accuracy +1.0% o.r. / +0.5% o.r.
Repeatability 0.16% o.r.
Turndown ≥ 20 : 1
Electrode 316L / HC / Titanium / Tantalum / Platinum-Iridium / Tungsten Carbide / Ceramic
Liner Neoprene / PTFE / PFA / HT PFA / PU / Ceramic / F46
Sensor Housing Carbon Steel / Stainless Steel
Power Supply 220V AC / 24V DC
Output 4~20mA HART + Frequency / Pulse + Modbus RS485
Diagnosis Empty Pipe Detection / Excitation Failure / Limit Alarm
Transmitter Compact / Remote Version
Installation Inlet Run ≥ 5 DN
Outlet Run ≥ 3 DN
Protection Degree IP66/67 / IP68 (Remote Sensor)
Ex Approval Ex db eb ib IIC T1…T6 Gb
Ambient Temperature -40°C ~ +60°C (LCD Display Guaranteed to Operate Above -20 °C)
Relative Humidity 5% ~ 95% RH

Request a Quote